亚洲一区二区视频,熟妇人妻久久中文字幕老熟妇,日韩精品无码熟人妻视频,亚洲亚洲人成网站网址

歡迎來到- 東莞市貢福電子有限公司 的官方網(wǎng)站, 汽車熔斷器、保險絲、電流保險絲、保險絲座!
提供標(biāo)準(zhǔn)及特殊規(guī)格的電路保護(hù)元件本公司產(chǎn)品可廣泛應(yīng)用于各電力設(shè)備領(lǐng)域的運用
全國銷售與服務(wù)熱線
0769 - 8239 1938
產(chǎn)品展示當(dāng)前位置:首頁 > 產(chǎn)品展示
GFPVT1000光伏熔斷器(10X38)DC1000V



[附件: Download]

Dimensions (mm)


Ferrule xxA-10R Dimensions


Axial bolt-on xxAP-10R Dimensions

Description



  • Low I2t value (low let-through energy)
  • Low voltage drop
  • Excellent DC performance
  • Variety of mounting options for flexibility

Standards & Approvals

  • Refer to UL-248-19 / IEC 60269-1/6
  • Reach declaration available upon request
  • RoHS compliant

Features & Benefits

  • The GFPVT1000 solar fuse is designed to integrate into an in-line assembly within a wire harness
  • Provides photovoltaic (PV) protection meeting UL 248-19 for photovoltaic applications
  • Can be electrically insulated by either over-molding or using heat-shrink
  • Meets IEC 60269-6 electrical performance requirements

Product Characteristics

Item Test condition/Methods Standard Performance
Time/Current 100% of current rating IEC 60269/UL248-19 No Fusing;4 hours Min.
113% of current rating *IEC IEC 60269 60 Minutes Min.
145% of current rating *IEC IEC 60269 60 Minutes Max.
105% of current rating *UL UL-248.19 60 Minutes Min.
135% of current rating *UL UL-248.19 60 Minutes Max.
200% of current rating IEC 60269/UL248-19;1-30A 4 Minutes Max.
IEC 60269/UL248-19;31-60A 6 Minutes Max.
Endurance Test 100% of rating current for 4 hours and testing Temperature rise at the last 5min. IEC 60269-6 UL248-19 ≤65K
  • Loading 100% Rated Current (1.0In A) for flowing, and it’s available to let current keep on flowing at least 4 hour without any melting.

Fuse Ratings


  • Ferrule xxA-10R


Part No. Fuse Amps Average @30KA/1000Vdc Power Loss (W) Approvals
A2s Melting A2s Clearing 80% 100% TUV
GFPVT1000-10A-10R 10 210 1175 1.1 1.5
GFPVT1000-12A-10R 12 252 1405 1.3 1.7
GFPVT1000-15A-10R 15 315 1757 1.6 2.3
GFPVT1000-16A-10R 16 326 1780 1.6 2.3
GFPVT1000-20A-10R 20 420 2340 2.1 2.9
GFPVT1000-25A-10R 25 525 2929 2.7 3.5
GFPVT1000-30A-10R 30 630 3515 3.2 4.2
GFPVT1000-32A-10R 32 890 3995 4 5.3
GFPVT1000-35A-10R 35 975 4545 4.6 6.2

Axial bolt-on xxAP-10R

Part No. Fuse Amps Average @30KA/1000Vdc Power Loss (W) Approvals
A2s Melting A2s Clearing 80% 100% TUV
GFPVT1000-10AP-10R 10 210 1175 1.1 1.5
GFPVT1000-12AP-10R 12 252 1405 1.3 1.7
GFPVT1000-15AP-10R 15 315 1757 1.6 2.3
GFPVT1000-16AP-10R 16 326 1780 1.6 2.3
GFPVT1000-20AP-10R 20 420 2340 2.1 2.9
GFPVT1000-25AP-10R 25 525 2929 2.7 3.5
GFPVT1000-30AP-10R 30 630 3515 3.2 4.2
GFPVT1000-32AP-10R 32 890 3995 4 5.3
GFPVT1000-35AP-10R 35 975 4545 4.6 6.2
  • DC Cold Resistance are measured at <10% of rated current in ambient temperature of 25℃